b. Cleaning and Inspection.
Clean all parts with cleaning solvent, Federal
Specification P-D-680, and dry thoroughly. Inspect
Dry cleaning solvent, P-D-680, used to clean
parts for cracks, dents, breaks, or other damage.
parts is potentially dangerous to personnel
Replace defective parts.
and property. Avoid repeated and
c. Assembly and Installation.
prolonged skin contact. Do not use near
(1) Assemble globe valve by installing screw (9,
open flame or excessive heat. Flash point of
solvent is 100F. (38C.) - 138F.
(5), bonnet (4) and nut (3) to body (10).
(59oC.).