TM 5-4310-356-14
WARNING
d. Draining Condensate from Receiver.
Dry cleaning solvent, P-D-680,
used to clean parts is potentially
(1) Turn ON-OFF switch to OFF.
dangerous to personnel and
property. Use in a well ventilated
(2) Open drain cock at bottom of the air
area as the fumes are dangerous
if inhaled. Avoid repeated and
(3) When the air has escaped, leave drain
prolonged skin contact. Do not
cock open for a few minutes to allow more of
use near open flame or excessive
condensate to escape.
heat. Flash point of solvent is
100 . -138 . (38 . -59 .).
F
F
C
C
(4) Close drain cock.
(5) Be sure that all rags, tools, etc., have
(2) Use a rag which has been dampened with
been removed from the air receiver, then move the
cleaning solvent, P-D-680, to remove all oil spots, then
ONOFF switch to ON.
dry thoroughly, to avoid further accumulation.
3-11/(3-12 blank)