TM 5-4310-356-14
4-5. Installation
a.
compressor as near to the electrical power source as
possible. Avoid muddy, sandy or dusty locations if
possible. If it is necessary to use the unit on soft
ground, provide a suitable, level foundation of planking.
b.
grounded prior to operation. The ground lead may be
connected to an under-ground water system if the water
system is constructed of metallic pipe. A ground may
be fabricated from a metallic rod driven not less than 4
feet into the ground. The ground lead must be securely
bolted or clamped to the water pipe or ground rod, and
the feet or motor platform of the air receiver tank of the
air compressor.
c. Connecting the Incoming Power Source.
(1) Remove the cover from the magnetic
(2) Remove knockout plug from the starter
box and insert the incoming power source wires through
the opening.
Figure 4-2. Air hose assembly, removal points.
4-2