TM 5-4310-368-14
Table 3-2. Troubleshooting Chart for the Operator (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
14. LOW 4th STAGE PRESSURE.
Step 1.
Check to see if pressure gage tubing fittings are leaking.
Step 2.
Check to see if condensate drain valve is leaking.
Notify organizational maintenance.
15. RECEIVER AIR PRESSURE WILL NOT RISE.
Step 1. Check to see if manual drain valve is leaking.
Repair/Replace.
16. HAND BRAKE DOES NOT HOLD .
Step 1. Check to see if hand brake is properly adjusted.
Adjust (page 1-27).
17. TIRE WEAR ABNORMAL.
Step 1.
Check to see if tires are properly inflated.
3-8