TM 5-4310-368-14
Section II. TROUBLESHOOTING
3-4.
TROUBLESHOOTING PROCEDURES
a. Table 3-2 lists the common malfunctions which you may find during the operation or maintenance of the
Model KA-15-03-P Bauer Compressor, or its components. You should perform the tests/inspections and
corrective actions in the order listed.
b. This manual cannot list all malfunctions that may occur, nor all tests or inspections and corrective actions. If
a malfunction is not listed or is not corrected by listed corrective actions, notify your supervisor.
Table 3-2. Troubleshooting Chart for the Operator
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. ENGINE FAILS TO START, OR HARD TO START.
Step 1.
Check to see if battery is fully charged.
Notify organizational maintenance.
Step 2.
Check to see if battery and starter cables are loose.
Step 3.
Check to see if fuel tank is empty.
Step 4.
Check to see if fuel filter is clogged.
Step 5.
Check to see if spark plugs dirty or damaged.
Notify organizational maintenance.
Step 6.
Check to see if magneto ground switch pushbutton is in grounded position.
Pull out on pushbutton.
3-4