TM 5-4310-368-14
Table 3-2. Troubleshooting Chart for the Operator (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. ENGINE STOPS SUDDENLY.
Step 1. Check to see if fuel tank is empty.
Step 2. Check cylinder head temperatures switch.
Step 3. Check to see if air cleaner restriction indicator is RED.
Notify organizational maintenance.
Step 1.
Check to see if drive belt has proper tension and is not worn.
6. COMPRESSOR OUTPUT LOW.
Step 1.
Increase speed: minimum - 1240 RPM, maximum - 1319 RPM.
Step 2. Check to see if air cleaner restriction indicator is RED.
Notify organizational maintenance.
Step 3. Check to see if condensate drain valve is leaking.
Notify organizational maintenance.
7. COMPRESSOR SPEED LOW.
Step 1. Check to see if drive belts have proper tension and are not worn.
Step 2 Check to see if engine is running at rated speed.
Increase speed (rated speed 2650 RPM).
8. COMPRESSOR WILL NOT LOAD.
Step 1.
Check to see if condensate drain valve is leaking.
Notify organizational maintenance.
Step 1.
Check to
see if
crankcase oil level is
low.
Step 2. Check to see if oil lines are leaking.
Step 3. Check to see if oil pump drive belts are worn or slipping.
10. COMPRESSOR OVERHEATING.
Step 1. Check to see if air inlet doors are open.
Step 2. Check to see if cooling fins are dirty.
Clean.
3-6