TM 5-4310-368-14
5-8.
This task covers:
a. Disassembly
c.
Inspection
b. Cleaning
d. Reassembly
INITIAL SETUP
Applicable Configurations
All
Equipment Condition
Paragraph
Condition Description
Alternator Removed from Engine
General Safety Precautions
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially
dangerous to personnel and property. Avoid repeated and prolonged
skin contact. Do not use near open flame or excessive heat. Flash
point of solvent is 100 (38 ) - 138 (59 ).
F
C
F
C
WARNING
Compressed air can be extremely hazardous. Use 30 PSI maximum air
pressure for parts cleaning.
a. Disassembly
(1)
Remove two nuts, one washer and nylon sleeve from isolation diode assembly. Remove isolation diode
assembly.
(2)
Remove two screws. Lift voltage regulator away from rear of alternator. Disconnect brush lead from
voltage regulator and remove voltage regulator from alternator.
(3)
Remove two screws from brush holder. Remove brush holder.
(4)
Remove four bolts and nuts.
(5)
Insert two flat blade screwdrivers into sides of alternator housing. Pry the rear alternator housing away
from the stator assembly and remove the rear housing.
NOTE
Do not insert screwdriver blade more than 1/16". Stator windings can be
damaged.
5-13