TM 5-4310-368-14
Figure 5-15. Air Lines, Hoses and Fittings
INITIAL SETUP
Applicable Configurations
All
General Safety Precautions
WARNING
Before working on any air hose, fitting or line, make sure all air pressure
has been released.
a. Disassembly
(1)
Disconnect air line from fitting.
(2)
Remove fitting body.
b. Repair. No repair is recommended. Defective parts must be replaced.
c.
Reassembly
(1)
Apply teflon tape to pipe thread joints.
(2)
Install and secure fitting body.
(3)
Reinstall air lines.
5-12