TM 5-4310-373-14
4-52. INFLATOR GAGE/REMOVAL/lNSTALLATION
This task covers:
The removal and installation of the inflator gage.
INITIAL SETUP
Tools:
Equipment Condition:
Shutoff valve closed or air in tank discharged
Materials/Parts:
As required
Personnel Required:
Approximate Time Required (minutes):
1 Mechanic
15
LOCATION/lTEM
ACTION
REMARKS
WARNING
Shutoff valve must be closed,
or air in tank must be dis-
charged before removal of
inflator gage. Removal under
pressure could cause serious
injury.
1. Shutoff valve (1)
Close.
2. Inflator gage (2)
a. Depress lever to discharge
remaining air in hose and
gage.
b. Remove from long hose by
disconnecting coupling (3).
c. Remove from short hose
by disconnecting coupling
(4).
Figure 4-92. Shutoff valve and inflator gage
1. Inflator gage (2)
a. Attach to long hose by
connecting coupling (3).
b. Attach to short hose by
connecting coupling (4).
2. Shutoff valve (1)
Open.
Figure 4-93. inflator gage assembly
4-87/(4-88 Blank)