TM 5-4310-377-13
3-12. PRESSURE SWITCH.
This task covers:
a. Removal
b. Cleaning c. Inspection
d. Repair
e. Installation
f. Adjustment
SET-UP:
Tools:
Pliers, water pump
1/2 inch wrench
1/4 inch wrench
Common screwdriver
Materials:
WARNING
Cleaning Solvent, Federal Specification P-D-680, is toxic and flammable. Use
solvent only in a well ventilated area. Avoid prolonged breathing of fumes. Keep
solvent away from flames. Do not use in excessive amounts. Avoid skin contact.
Personnel:
1 Person
Equipment Conditions:
Electrical power removed at master control panel. Tank drain cock open and air
GO TO NEXT PAGE
3-23