TM 5-4310-377-13
Section VI. MAINTENANCE OF MOTOR CONTROLS
Para.
Para.
Motor Starter Box
Pressure Switch
Assembly ..................................................... 3-11f
Adjustment ................................................... 3-12f
Cleaning ....................................................... 3-11c
Cleaning ....................................................... 3-12b
Disassembly ................................................. 3-11b
Inspection ..................................................... 3-12c
Inspection ..................................................... 3-11d
Installation .................................................... 3-12e
Installation 3 .................................................. 3-11g
Removal ....................................................... 3-12a
Removal........................................................ 3-11a
Repair .......................................................... 3-12d
Repair .......................................................... 3-11e
3-11. MOTOR STARTER BOX.
This task covers:
a. Removal
b. Disassembly
c. Cleaning
d. Inspection
e. Repair
f. Assembly
g. Installation
SET-UP:
Tools:
Common screwdriver
Phillips screwdriver
Pliers, water pump
1/4 inch wrench (2 each)
Materials:
WARNING
Cleaning Solvent, Federal Specification P-D-680, is toxic and flammable. Use
solvent only in a well ventilated area. Avoid prolonged breathing of fumes. Keep
solvent away from flames. Do not use in excessive amounts. Avoid skin contact.
Personnel:
1 Person
Equipment Conditions:
Electrical power removed at master control panel.
Tank drain coc k open and air bleed off (para. 2-2a &b).
GO TO NEXT PAGE
3-17