TM 5-4310-378-14
(2) Installation
(a) Install fittings removed in step b.
(b) Fit tubes into place and start nuts on each end onto their fittings.
(c) Tighten tube nuts to secure the assembly.
3-16. INTERSTAGE RELIEF VALVE
This task covers:
a. Inspection
b. Replacement
Tools: 5/8-in. wrench
Solvent, Dry Cleaning
Interstate Safety Valve
Equipment Condition: Ignition switch
a. I n s p e c t i o n
WARNING
I
Dry Cleaning Solvent
(Stoddard Solvent)
P-D-680
Combustible - do not use near open flames, near welding areas, or on hot sur-
q
faces.
Prolonged or repeated contact of skin with liquid can cause dermatitis. Re-
q
peated inhalation of vapor can irritate nose and throat and can cause dizzi-
ness.
If any liquid contacts skin or eyes, immediately flush affected area thoroughly
q
with water. Remove solvent-saturated clothing. If vapors cause dizziness, go
to fresh air.
When handling liquid or when applying it in an air-exhausted, partially cov-
q
ered tank, wear approved gloves.
When handling liquid or when applying it at an unexhausted, uncovered tank
q
or workbench, wear approved respirator, goggles, and gloves.
(1) Clean interstage safety valve (1) as necessary to perform inspection. Use brush, rag, and solvent as required.
(2) Inspect for leaking, wear or damage.