4-60. SLAVE RECEPTACLE REPLACEMENT.
b. INSTALLATION - TM-5-4310-452-14_177
TM-5-4310-452-14 Compressor Air: Rotary Screw 750 CFM 100 PSI Wheel-Mounted DED SULLIAR Model 750 DP Manual
Page Navigation
163
164
165
166
167
168
169
170
171
172
173
TM 5-4310-452-14
4-61. MAGNETIC STARTER SWITCH REPLACEMENT.
This Task Covers:
a. Removal
b. Installation
Initial Setup:
Equipment Conditions:
Materials/Parts:
• Four lockwashers
• Engine off.
• Right door assembly open.
Tools/Test Equipment:
• Battery cables disconnected (see paragraph
4-57).
• General mechanic's tool kit
a.
REMOVAL
1.
Remove 2 screws (5) from bracket (6).
2.
Remove 2 nuts (10),
lockwashers
(9), and 3 electrical leads (8) from magnetic starter switch (4). Discard
lockwashers.
3.
Remove 2 nuts (1),
lockwashers
(2), and electrical leads (11) from magnetic starter switch (4). Discard lockwashers.
4.
Remove 2 screws (3), nuts (7), and magnetic starter switch (4) from bracket (6).
4-114