TM9-4310-396-13
3-2.4 All procedural instructions assume that the compressor is shutdown before attempting any procedures and that all
access doors are opened.
3-2.5 For Operator troubleshooting procedures refer to Table 3-1.
OPERATOR TROUBLESHOOTING TABLE 3-1
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. ENGINE WILL NOT START.
Step 1. Check condition of fuel tank cap vent.
Ensure that vent is open.
Step 2. Check primary fuel tank to insure adequate fuel.
WARNING
Fuel used in operating this compressor
is explosive. Do not refuel during
operation. Avoid open flame near fuel
tank filler neck. Keep cap on fuel tank
except during refueling. Failure to
observe this warning may result in severe
personal injury or death.
Add fuel.
Step 3. Check to see if fuel engine knob is pulled out.
Push in fuel engine knob.
Step 4. Check fuel remote control lever is in normal "up" position.
Raise remote control lever.
Step 5. Condition continues.
Notify Unit maintenance.
3-2