TM9-4310-396-13
CAUTION
When boost starting an engine, refer to para. 2-6.7 to properly start engine. Engine
is equipped with 12 VDC starting system. Use only equal voltage for boost starting.
Use of higher voltage will damage electrical system.
f. To start engine with jumper cables use 12 VDC, DC battery source.
g. Report to Unit maintenance if these methods are unsuccessful.
CAUTION
Do not allow small items to be drawn into the intake to prevent potential damage
to compressor and/or engine.
NOTE
Key switch alone will not stop engine. To stop engine, pull engine knob (1, Figure 2-9)
on frame control panel. By pulling knob, fuel will be shut off and engine will stop.
2-14.2 Engine Emergency Shut Off Procedures. If engine knob when pulled as detailed in paragraph 2-6.7 does not stop
engine, then as a last resort the operator may do one of the following: a) push remote control lever (2, Figure 2-10) or b)
restrict air flow into intake air cleaner (2, Figure 2-8) by placing a cloth over it.
2-15 NUCLEAR, BIOLOGICAL, AND CHEMICAL (NBC) DECONTAMINATION PROCEDURES
2-15.1 General. In the event nuclear, biological, and/or chemical agents come into contact with the compressor, the
operator should cease all contact and report to their immediate supervisor the status. Any decontamination procedures
shall be directed by the procedures in Army use by the qualified persons. The following emergency procedures can be
performed until field (NBC) decontamination facilities are available. Commander will supervise, assign crew duties, and
assist the supporting NBC unit.
2-15.2 Emergency Procedure. If NBC attack is known or suspected, mask at once and continue mission.
Follow decontamination procedures. Do not unmask until told to do so.
a. Nuclear Decontamination. Brush fallout from skin, clothing, and equipment with available brushes, rags, and tree
branches. Wash skin and have radiation check made as soon as tactical situation permits.
b. Biological Decontamination. Remain masked and continue mission until told to unmask. Use authorized chemical
agent detector kit. If exposed by known or suspected agent, clean exposed and personal gear in that order using
approved system as soon as tactical situation permits.
2-42