(3) Inspect brushes and springs for excessive
WARNING
wear, cracks, distortion, or any other
defect.
Dry cleaning solvent, P-D-680, used
to
clean
parts
is
potentially
(4) Inspect attaching hardware for distortion,
dangerous
to
personnel
and
cracks, breaks, damaged threads, or any
property.
Avoid repeated and
other defect.
prolonged skin contact. Do not use
near open flame or excessive heat.
c. Installation. Install the starting motor assembly
Flash point of solvent is 100 F-130 F
(38 C-59 C).
clamps on battery terminals.
b. Cleaning and Inspection.
(1) Clean exterior surfaces of the starting
WARNING
motor assembly with a clean cloth soaked
with solvent, Federal Specification PD-
Disconnect battery cable clamps
680, Type II. Dry thoroughly. Blow any
from
battery
terminals
before
dust and dirt out of the inside of the
assembly with dry compressed air.
(2) Inspect the drive assembly gear teeth for
chipping, cracks, and broken teeth, or any
other defects.
4-49