TM 5-4310-380-13
3-11. MOTOR STARTER BOX - Continued.
g. Installation - Continued.
(6) Connect the conduit and power source wiring per the tagged identification.
(7) Close door (3) and slip clamps (2) over lip of door. Tighten both screws (1).
3-12. PRESSURE SWITCH.
This task covers:
a. Removal
b. Cleaning
c. Inspection
d. Repair
e. Installation
f. Adjustment
SET-UP:
Tools:
Pliers, water pump
1/2 inch wrench
3/4 inch wrench
Common screwdriver
Jeweler screwdriver
Materials:
WARNING
Cleaning Solvent, Federal Specification P-D-680, is toxic and flammable. Use solvent only in a
well ventilated area. Avoid prolonged breathing of fumes. Keep solvent away from flames.
Do not use in excessive amounts. Avoid skin contact.
Personnel:
1 Person
Equipment Conditions:
Electrical power removed at master control panel.
Tank drain cock open and air bled off (para. 2-4a & b).
GO TO NEXT PAGE
3-17