TM 5-4310-451-14
5-101. AIR COMPRESSOR ASSEMBLY REPAIR (Cont).
b. CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles and
gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO
NOT breathe vapors. DO NOT use near open flame or excessive heat. The solvents flash point is
100iF-1380F (380C-590C). If you become dizzy while using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts eyes, immediately wash your eyes and get medical aid.
1.
Clean parts with dry cleaning solvent. Allow to dry.
2.
Inspect parts for damage. Replace damaged parts.
c. INSTALLATION
1.
Install six bolts (8) and new locknuts (7) on hub (3), gear (4), and plate (5).
2.
Install plate (5), gear (4), and hub (3) on air compressor shaft (6).
NOTE
It may be necessary to tap wedgelock on air compressor shaft.
3.
Install wedgerock (9) and key (2) on air compressor shaft (6).
4.
Aline holes in hub (3), gear (4), and plate (5) and aline two threaded holes in wedgelock (9) and hub.
5.
Apply lubricating oil to threads of two setscrews (1) and install setscrews in two threaded holes in wedgelock (9)
and hub (3). Torque setscrews to 35-37 lb.-ft. (48-50 Nám).
FOLLOW-ON TASKS:
Install air compressor assembly (see paragraph 5-100).
5-377