TM 5-4310-368-14
a.
Removal
(1)
Remove screw and nut from each of two check cables.
NOTE
Check cables not installed on control panel access door.
(2)
Remove three screws and nuts from each door hinge. Remove doors.
b.
Disassembly
(1)
Loosen pinch bolt at rear of each latch. Remove control cable.
(2)
Remove four screws and nuts from each latch. Remove latch.
(3)
Remove four screws and nuts from each latch operator. Remove latch operators.
c.
Repair
(1)
Repair door panels as required.
(2)
Repaint door panels with proper paint.
d.
Reassembly
(1)
Position latch operator over hole in door panel.
(2)
Align bolt holes in operator with bolt holes in door panel.
(3)
Install and secure four screws and nuts in latch operator.
(4)
Position two latches over ends of each door panel.
(5)
Align bolt holes in latch with bolt holes in door panel.
(6)
Install and secure four screws and nuts in each latch.
(7)
Thread end of control cable under pinch bolt on each latch.
(8)
Adjust control cables so that each latch fully opens at the same time.
(9)
Secure pinch bolts.
e.
Installation
(1)
Position door over proper opening in enclosure.
(2)
Align bolt holes in door hinge with bolt holes in enclosure.
(3)
Install and secure three screws and nuts in each hinge.
4-16