TM-5-4310-389-14
Figure 5-55. Correct Installation of Radial Seal
1.
Remove the starter mounting flange. Remove the studs securing the rear end shield and withdraw the end shield
with puller device No. 003-0672 (figure 5-56).
2.
Remove the gasket. Check the rear end shield. Check the contact surface of the radial sealing ring. If it exhibits
a groove, change the location of the radial sealing ring in the end shield.
3.
Slide the protective sleeve onto the end of the crankshaft. Coat a new gasket with grease and stick it in position on
the end shield. Lightly coat the lip of the radial sealing ring with grease. Position the end shield so that its oil holes
register with those in the crankcase (use protective sleeve of special device No. 003-0670).
4.
Tighten the nuts of the tool uniformly, in diagonal sequence (use special device No.003-0670).
5.
Tighten the studs uniformly and in diagonal sequence.
6.
Install the flange mounting plate (figure 5-57).
Figure 5-56. Removing End Shield
Figure 5-57. Install the Flange Mounting
Plate
5-33