TM-5-4310-389-14Figure 5-55. Correct Installation of Radial Seal1.Remove the starter mounting flange. Remove the studs securing the rear end shield and withdraw the end shieldwith puller device No. 003-0672 (figure 5-56).2.Remove the gasket. Check the rear end shield. Check the contact surface of the radial sealing ring. If it exhibitsa groove, change the location of the radial sealing ring in the end shield.3.Slide the protective sleeve onto the end of the crankshaft. Coat a new gasket with grease and stick it in position onthe end shield. Lightly coat the lip of the radial sealing ring with grease. Position the end shield so that its oil holesregister with those in the crankcase (use protective sleeve of special device No. 003-0670).4.Tighten the nuts of the tool uniformly, in diagonal sequence (use special device No.003-0670).5.Tighten the studs uniformly and in diagonal sequence.6.Install the flange mounting plate (figure 5-57).Figure 5-56. Removing End ShieldFigure 5-57. Install the Flange MountingPlate5-33