TM 5-4310-368-14
INITIAL SETUP
Applicable Configurations
All
a.
Testing
(1)
Turn master switch on. Fuel gage should register.
(2)
If fuel gage does not move, verify fuel level in tank.
(3)
If fuel is in tank and gage does not register, short center terminal of fuel level sender to ground. Fuel
gage should go to "full."
(4)
If fuel gage does not go to "full," check voltage at gage with multimeter.
(5)
If proper voltage is at gage, replace gage.
b.
Removal
(1)
Disconnect wire harness at three places. Mark wire for reassembly.
(2)
Remove nut, washer and saddle clamp from rear of fuel gage. Remove fuel gage.
c.
Installation
(1)
Position fuel gage into hole in instrument panel.
(2)
Position saddle clamp over stud in back of fuel gage.
(3)
Secure saddle clamp with nut and washer.
(4)
Connect wire harness in three places.
4-53.
BATTERY, BATTERY HOLD-DOWN AND BATTERY CABLES
This task covers:
a.
Removal
d.
Install Battery Cables
b.
Inspection
e.
Test Battery
c.
Remove Battery Cables
f.
Install Battery and Hold-Down
4-52